The sewer backflow preventer DN 160 effectively protects rooms located on the lowest floors from flooding caused by rainwater or sewage backflow. Backflow can be caused by heavy rainfall, snow melt or flooding. People also sometimes use the DN 150 designation, however, these dampers are identical. It is always the same product, namely DN 160. This check damper must be installed horizontally. Advantages and uses of the sewer check valve DN 160: made of high quality, corrosion-resistant, durable polypropylene, resistant to negative temperatures and chemicals effectively protects against rodents prevents the release of unpleasant odours careful design high-quality materials used in the manufacturing process interior of the device with smooth and properly profiled surface prevents the accumulation of sediments and ensures unhindered flow of sewage The highest quality flexible materials with increased resistance to weathering and ageing have been used for the production of the seals The use of flood protection devices in low-lying rooms is required by the applicable technical regulations, which buildings must comply with. Properties of the DN 160 sewer backflow preventer: the flap cover as well as all fastening elements (bolts, nuts, washers) are made of chrome-nickel stainless steel the backflow preventer is equipped with a manual closing lever by moving the lever from the OPEN A to the CLOSED B position the backflow of sewage water is completely stopped the total deflection of the flap ensures 100% flow through the pipe simple and efficient closing mechanism easy assembly self-functioning, requires no external power supply maximum operating temperature 95°C maximum operating pressure 0.5 bar valve has successfully passed the series of tests required by PN-EN 13564 and has been awarded the CE marking Technical drawing:
A manhole bottom backflow preventer is a device that effectively blocks the backflow of sewage. Advantages of a backflow preventer: effective protection of buildings low cost and easy installation possibility of removing the check damper on the ground surface without entering the manhole no need to call a specialist for maintenance resistance to corrosion, negative temperatures and chemicals the valve has successfully passed a series of tests required by PN-EN 13564 and has been awarded the CE marking The
The sewer backflow preventer DN 110 effectively protects rooms located on the lowest floors from flooding caused by rainwater or sewage backflow. Backflow can be caused by heavy rainfall, snow melt or flooding. People also sometimes use the DN 100 designation, however, these dampers are identical. It is always the same product, namely DN 110. This check damper must be installed horizontally. Advantages and uses of the DN 110 sewer check valve: made of high quality, corrosion-resistant, durable polypropyle
Check Valve - 3/8 Mx3/8 F PN 10, T = +120 °C external thread - internal MF material brass CW617N
Check Valve - 1/2 Mx3/8 M PN 10, T = +120 °C external thread - internal MF material brass CW617N
Check valve EURA - light, FIV.08030, Dimension: 1/2" FF, Package: 20 pcs PN 16, T = +80 °C
Backflap, IVAR.ACVR, size: 1/4" F x 1/2" M check valve for thermomanometers and manometers
The end sewer flap DN 110 effectively protects the installations against the entry of rats into the building. The sewer end flap is not a shut-off fitting. Advantages of the sewer end flap DN 110: it is made of plastic with the addition of a stabiliser to increase resistance to sunlight and other weather conditions the specially designed drainage end valve protects drainage installations from backflow and clogging in the event of water level rising above the drain level it is installed directly at the end
The end sewer flap DN 200 effectively protects the installations against the entry of rats into the building. The sewer end flap is not a shut-off fitting. Advantages of the end sewer flap DN 200: it is made of plastic with the addition of a stabiliser to increase resistance to sunlight and other weather conditions the specially designed drainage end valve protects drainage installations from backflow and clogging in the event of water level rising above the drain level it is installed directly at the end
The end sewer flap DN 160 effectively protects the installations against the entry of rats into the building. The sewer end flap is not a shut-off fitting. Advantages of the end sewer flap DN 160: it is made of plastic with the addition of a stabiliser to increase resistance to sunlight and other weather conditions the specially designed drainage end valve protects drainage installations from backflow and clogging in the event of water level rising above the drain level it is installed directly at the end
Check valve EURA - light, FIV.08030, Dimension: 3/4" FF, Packing: 12 pcs PN 16, T = +80 °Copening overpressure 0.02 barflow rate Kv 7.11thread internal - internal FF
Check valve EURA light - 5/4 FF; Kv 19,45 PN 16 - 1/2 to 1 , PN 10 - 5/4 to 2 , T = +80 °C Opening overpressure 0.02 bar internal thread - internal FF material brass CW617N, polymer orifice ATEST for drinking water
Check valve EURA light - 1 FF; Kv 10,91 PN 16 - 1/2 to 1 , PN 10 - 5/4 to 2 , T = +80 °C Opening overpressure 0.02 bar internal thread - internal FF material brass CW617N, polymer orifice ATEST for drinking water
Eura heavy duty check valve - 5/4 FF; Kv 7,50 PN 15, T = +90 °C opening overpressure 0,02 bar internal thread - internal FF material brass CW617N, polymer orifice ATEST for drinking water
Eura heavy duty check valve - 2 1/2 FF; Kv 21,00 PN 15, T = +90 °C opening overpressure 0,02 bar internal thread - internal FF material brass CW617N, polymer orifice ATEST for drinking water
Eura heavy duty check valve - 2 FF; Kv 15,00 PN 15, T = +90 °C opening overpressure 0,02 bar internal thread - internal FF material brass CW617N, polymer orifice ATEST for drinking water