Technical information and equipment:
power output 40kW at ∆t = 20K
max. volumetric flow rate 2,58m3/h
max. operating pressure 6 bar
DN 40
2 x GV DN40 with integrated thermometer
bypass with integrated non-return valve - spacer 50mm piece
2 x 1/2 plug
all gaskets
wall mounting
EPP thermal insulation
exterior dimension with insulation H x W x D: 320 x 480 x 215 mm
pump AVANSA 25-6-180
ROTOTOTEMP FX3 electronic programmable unit to maintain a constant flow temperature
Select the necessary accessories for wiring:
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated check valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm DAB Evosta 40 - 70/180 pump electronic programmable ROTOTEMP FX3 unit to maintain a constant flow temperature Select the necessary acce
Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm AVANSA 25-6-180 pump electronic programmable ROTOTEMP C unit to maintain a constant flow temperature
Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm DAB Evosta 40 - 70/180 pump electronic programmable unit ROTOTEMP C to maintain a constant flow temper
Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm AVANSA 25-6-180 pump electronic programmable unit ROTOTEMP C to maintain a constant flow temperature
Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm DAB Evosta 40-70/180 pump electronic programmable ROTOTEMP C unit to maintain a constant flow temperat
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated non-return valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm pump AVANSA 25-6-180 FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessories for wiring:
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated non-return valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm DAB Evosta 40-70/180 pump FIRST® 230V, 24V or 0-10 servo drive Select the necessary accessories for wiring:
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated non-return valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessories for wiring:
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated non-return valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessories for wiring:
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated non-return valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessories for wiring:
Technical information and equipment: power 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ bypass backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm AVANSA 25-6-180 pump FIRST® 230V, 24V or 0-10V servo drive Select the necessary accessories f
Technical information and equipment: power output 20kW, at ∆t = 20K max flow rate 0.86 m3/h max. operating pressure 6 bar connection spacing to header 125 mm DN1 2x GV DN25 with integrated thermometer, 1x GV DN25 1 x 1 pipe, in place for pump with 1½ backflow preventer all gaskets, 2 x 1/2 plugs EPP thermal insulation wall fixings exterior dimension with insulation H x W x D: 525 x 250 x 225 mm pump AVANSA 25-6-180 Select the necessary accessories for wiring:
Technical information and equipment: power output 40kW at ∆t = 20K max. volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x GV DN40 with integrated thermometer bypass with integrated non-return valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm without actuator without pump /L=180 mm/
2 to 5 circuits: power 60kW, at ∆t = 20K, flow rate 2,6 m3/h DN40 x 1,5 for boiler assemblies connection spacing 125 mm, 1 female thread divider outlet 5/4 with overflow nut EPP thermal insulation 1 circuit: power 60kW, at ∆t = 20K, flow rate 2,6 m3/h DN40 x 1,5 for boiler assemblies connection spacing 125 mm, 1 female thread manifold outlet 5/4 male thread with gasket includes 2 x nipple
Technical information and equipment: power output 60kW at ∆t = 20K max volumetric flow rate 2,58m3/h max. operating pressure 6 bar DN 40 2 x ball valve DN40 with integrated thermometer (0-120°C) 1 x ball valve DN 40 bypass with integrated check valve - spacer 50mm piece 2 x 1/2 plug all gaskets wall mounting EPP thermal insulation exterior dimension with insulation H x W x D: 320 x 480 x 215 mm AVANSA 25-6-180 pump Select the necessary accessories for wiring: